TM-5-4210-249-13-P-2

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 2 OF 4

  TM-5-4210-249-13-P-2 - Page 595 of 1452

TM 5-4210-249-13&P-2
0169-7/(8 blank)
DRAFT
0169
END OF TASK
FOLLOW-ON MAINTENANCE
Remove wheel chocks (TM 9-2320-347-10)
END OF TASK
END OF WORK PACKAGE
TFFT04212
Step 11.
Check for 22 to 28 VDC between cord reel rewind motor power cable at rear
compartment heater circuit breaker and a known good ground.
If 22 to 28 VDC are not present, repair high amperage 4 gauge cable if
repairable (TM 9-2320-325-14&P), or replace high amperage 4 gauge cable
from frame B+ stud and rear compartment heater circuit
breaker (WP 0393).
Step 12.
Check for 22 to 28 VDC between cord reel rewind motor power cable at cord reel
rewind circuit breaker and a known good ground.
a.
If 22 to 28 VDC are present, replace cord reel rewind motor power wire
between cord reel rewind circuit breaker and cord reel rewind
solenoid (WP 0393).
b.
If 22 to 28 VDC are not present, repair wire if repairable
(TM 9-2320-325-14&P), or replace cord reel rewind motor power wire
between rear compartment heater circuit breaker and cord reel rewind
circuit breaker (WP 0393).


Back to Top