TM-5-4210-249-13-P-2

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 2 OF 4

  TM-5-4210-249-13-P-2 - Page 604 of 1452

TM 5-4210-249-13&P-2
0171-2
DRAFT
0171
TFFT04510
NOTE
Hydraulic generator provides power for the following components:
air conditioner, cord
reel, receptacles, extendable floodlights, 120-volt receptacles, water heaters, heat trace,
and reciprocating saw battery charger receptacles.
If any of these components operate,
troubleshoot the component that does not operate before performing this procedure.
Step 1.
Turn battery disconnect switch to ON position (WP 0007).
Start hydraulic generator
(WP 0021).
Check if GEN PTO ENGAGED indicator illuminates.
If GEN PTO ENGAGED indicator does not illuminate, troubleshoot GEN
PTO ENGAGE Indicator Does Not Illuminate (Cab) (WP 0139).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top