Step 11.
Remove pump house panel G (WP 0540).
Disconnect pump house wire harness pump
house heater 2-terminal connector.
With a test lead set, check for continuity across
wire 4090 (purple) from pump house wire harness pump house heater 2-terminal
connector terminal 2, to main wire harness pump house heater fuel pump, terminal.
If there is continuity, replace pump house heater (WP 0469).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION