Step 16.
Turn battery disconnect switch to OFF position (WP 0007).
Remove jumperwire from
pump house wire harness pump house heater diagnostic module connector.
Remove
pump house panel G (WP 0540).
Disconnect pump house wire harness pump house
heater 4-terminal connector.
With a test lead set, check for continuity across pump
house wire harness wire 4087 (blue) from pump house wire harness pump house
heater diagnostic module connector, terminal C to pump house wire harness pump
house heater 4-terminal connector, terminal 4.
If there is no continuity, repair wire 4087 in pump house wire harness if
repairable (TM 9-2320-325-14&P), or replace pump house wire harness
(WP 0458).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION