TM-5-4210-249-13-P-2

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 2 OF 4

  TM-5-4210-249-13-P-2 - Page 773 of 1452

TM 5-4210-249-13&P-2
0182-23
DRAFT
0182
TFFT04741
Step 28.
Remove pump house panel G (WP 0540).
Disconnect pump house wire harness pump
house heater 3 terminal connector.
With a test lead set, check for continuity across wire
1640 (black) from pump house wire harness pump house heater 3-terminal connector,
terminal C to a known good ground.
a.
If there is continuity, replace pump house heater (WP 0469).
b.
If there is no continuity, repair wire 1640 in pump house wire harness if
repairable (TM 9-2320-325-14&P), or replace pump house wire
harness (WP 0458).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top