MOTOR OVERLOAD CONTACTOR REMOVAL
NOTE
Tag and mark wires prior to removal to ensure proper installation.
Remove cable ties as required.
1.
Loosen six screws (1) and remove wires (2) from motor overload contactor (3).
2.
Separate two contactor halves (4) and (5).
3.
Remove two locknuts (6) from motor overload contactor (3) and control box (7). Discard locknuts.
END OF TASK
MOTOR OVERLOAD CONTACTOR INSTALLATION
NOTE
Install cable ties as required.
1.
Install motor overload contactor (3) in control box (7) with two locknuts (6).
2.
Join two contactor halves (4) and (5).
3.
Install six wires (2) on motor overload contactor (3), and tighten four screws (1).