TM-5-4210-249-13-P-3

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 3 OF 4

FEBRUARY 2009

  TM-5-4210-249-13-P-3 - Page 1429 of 1488

TM 5-4210-249-13&P-3
0561-1
DRAFT
0561
FIELD LEVEL MAINTENANCE
WINDSHIELD DELUGE PUMP HOUSE STRAINER SCREEN REPLACEMENT
INITIAL SETUP:
REMOVAL
1.
Remove cap (1), gasket (2), and screen (3) from strainer (4).
2.
Remove plug (5) from cap (1).
END OF TASK
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
TFFT00721
Tools and Special Tools
Tool Kit, General Mechanic’s: Automotive
(WP 0622, Item 27)
Materials/Parts
Compound, Sealing, Pipe Thread
(WP 0625, Item 21)
References
WP 0615, Fig. 172
Equipment Conditions
Pump house panel A opened (WP 0539)
Water system drained (WP 0041)


Back to Top