TM-5-4210-249-13-P-3

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 3 OF 4

FEBRUARY 2009

  TM-5-4210-249-13-P-3 - Page 29 of 1488

TM 5-4210-249-13&P-3
0294-3
DRAFT
0294
INSTALLATION
1.
Install adapter (15) on valve (11) with four screws (14).
2.
Install adapter (12) on valve (11) with four screws (13).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing.
To avoid injury or death, keep away
from open fire and use in well-ventilated area.
If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
CAUTION
Use sealing compound sparingly only on pipe threads.
Do not apply compound to
hose connections.
Damage to equipment may result.
3.
Apply sealing compound to threads of elbow (3).
4.
Install elbow (3) on adapter (12).
5.
Install electric motor and drive assembly (10) on valve (11) (WP 0388).
6.
With the aid of an assistant, install pipe (8) on bracket (9) and vehicle with cradle (7), U-bolt (6), and two
locknuts (5).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
- -
-
-
-
-
-
-
-
-
-
-
WARNING
ICON 30, 44, 27


Back to Top