TM 5-4210-249-13&P-3
0426-1
DRAFT
0426
FIELD LEVEL MAINTENANCE
SHUTOFF CONTROL VALVE DIODE PACK REPLACEMENT
INITIAL SETUP:
REMOVAL
NOTE
Both shutoff control valve diode packs are removed the same way.
1.
Remove cover (1) from diode connector (2).
NOTE
Note position of diode prior to removal to ensure proper current flow following installation.
2.
Remove diode (3) from diode connector (2).
END OF TASK
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
TFFT01319
Tools and Special Tools
Tool Kit, General Mechanic’s: Automotive
(WP 0622, Item 27)
Equipment Conditions
Pump house panel S removed (WP 0540)