TM-5-4210-249-13-P-3

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 3 OF 4

FEBRUARY 2009

  TM-5-4210-249-13-P-3 - Page 592 of 1488

TM 5-4210-249-13&P-3
0438-2
DRAFT
0438
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2.
Disconnect cab discharge digital pressure gauge connector (3) from pump discharge pressure transducer
connector (4).
3.
Disconnect cab discharge digital pressure gauge connector (5) from pump operator’s panel discharge digital
pressure gauge (6), and remove cab discharge digital pressure gauge wire harness (7) from vehicle.
END OF TASK
INSTALLATION
NOTE
Install cab discharge digital pressure gauge wire harness as noted prior to removal.
Install cable ties, split looms, and cushion clips as noted.
1.
Position cab discharge digital pressure gauge wire harness (7) on vehicle, and connect cab digital pressure
gauge connector (5) on pump operator’s panel discharge digital pressure gauge (6).
2.
Connect pump discharge pressure transducer connector (4) on cab discharge digital pressure gauge
connector (3).
TFFT04199