TM 5-4210-249-13&P-3
0458-17
DRAFT
0458
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
28. Install fuse (30) in fuse holder (31).
29. Install fuse (28) in fuse holder (29).
30. Install wire 4064 (27) and wire 1590 (26) on pump primer solenoid (17) with lockwasher (25) and nut (24).
31. Install wire 4065 (23) on pump primer solenoid (17) with lockwasher (22) and nut (21).
32. Install wire 4065 (20) on pump primer solenoid (17) with lockwasher (19) and nut (18).
33. Install jumperwire 2768 (16) on pump primer solenoid (17) with lockwasher (15) and nut (14).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing.
To avoid injury or death, keep away
from open fire and use in well-ventilated area.
If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
34. Apply sealing compound to electrical connections on pump primer solenoid (17).
TFFT03267
WARNING
ICON 30, 44, 27