TM 5-4210-249-13&P-3
0476-4
DRAFT
0476
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
6.
Install insulation wrap (2) on water pump engine turbo charger (3) with safety wire (1).
END OF TASK
FOLLOW-ON MAINTENANCE
1.
Install pump engine radiator (WP 0481)
2.
Install thermostat housing and upper coolant tube (WP 0249)
3.
Fill pump engine coolant (WP 0479)
4.
Install water pump engine noise panel (WP 0242)
5.
Close pump house panel (WP 0325)
6.
Install pump house panels G, H, I, S, T, and U (WP 0540)
END OF TASK
END OF WORK PACKAGE
TFFT01650A