TM-5-4930-237-10

HEMTT TANKER AVIATION REFUELING SYSTEM (HTARS)

OPERATOR’S MANUAL

MARCH 1989
CHANGE 5

  TM-5-4930-237-10 - Page 27 of 80

TM 5-4930-237-1O
Key
44
45
46
47
48
49
50
51
52
53
54
55
56
57
Control or Indicator
Fuel Sampling Hose
Plug
Release Pin
Strainer Housing
D1 Nozzle
Dust Cap
Dust Cap
Interlock Pin
Retainer
Strainer
Flow Handle
Rod, Grounding
Striker
Hanger Assembly
Function
Used to obtain sample of fuel.
Closes fuel sample port when fuel sampling hose not
connected.
Allows FLOW handle to open to inspect strainer
housing.
Opens flow valve in aircraft.
Dispenses fuel to aircraft.
Keeps dirt and contaminants out of nozzle.
Keeps ,dirt and contaminants out of nozzle.
Locks nozzle to hose.
Holds strainer in nozzle.
Prevents damage to nozzle and /or aircraft by
removing dirt.
Opens and closes valve.
Grounds and bonds aircraft to HTARS System.
Part of the grounding rod.
Part of the grounding rod.
Figure 2-1. Operator’s Controls and Indicators (Sheet 8 of 8)
Section II. PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS)
2-2. General.
a.
Before you operate the equipment, perform your before (B) PMCS. Always keep in mind the
WARNINGS and CAUTIONS.
b.
While you operate the equipment, perform your during (D) PMCS. Always keep in mind the
WARNINGS and CAUTIONS.
c.
After you operate the equipment, perform your after (A) PMCS.
d.
If your equipment fails to operate, troubleshoot with the proper equipment. Report any defi-
ciencies using the proper forms. Refer to DA PAM 738-750, The Army Maintenance Management System.
2-3. PMCS Procedures. (See Table 2-1.)
a.
The purpose of the PMCS table is to identify each component which requires inspection to insure
operational readiness.
b. The service intervals have been selected to ensure all components are inspected regularly.
2-8 Change 1


Back to Top