TM-5-4930-237-10

HEMTT TANKER AVIATION REFUELING SYSTEM (HTARS)

OPERATOR’S MANUAL

MARCH 1989
CHANGE 5

  TM-5-4930-237-10 - Page 35 of 80

TM 5-4930-237-10
2-11.
Operation of Recirculation Nozzle.
a.
b.
c.
d.
e.
f.
g.
h.
WARNING
Ground and bonding plugs must be connected before attaching nozzle to
aircraft. Failure to comply can result in injury or death to personnel from
static discharge.
Connect ground and bonding plugs (42) to aircraft.
Wipe around fuel receptacle with a clean cloth (Item 1, Appendix D) to remove dirt or dust.
Remove fuel cap from fuel receptacle.
CAUTION
Be sure plug (45) is installed in nozzle and hand-tight. Failure to comply can
result in fuel leakage.
Remove dust cap (39).
Connect recirculation nozzle (38) to fuel receptacle as follows:
(1)
Grasp handle grips and align inlet with fuel receptacle.
(2)
Press recirculation nozzle (38) against fuel receptacle and turn to align pins.
(3)
Push recirculation nozzle (38) against fuel receptacle and turn clockwise until nozzle stops.
NOTE
Handle on CCR nozzle must be in FLOW position. Refer to TM 6-4930-236-
13&P for details.
Put FLOW handle (41) in flow position.
When fuel tank is full put FLOW handle (41) in closed position.
Turn counterclockwise and remove recirculation nozzle (38) from fuel receptacle and install dust
cap (39).
2-16
Change 1


Back to Top