0037
TM 5-5420-202-10
GAS AND PARTICULATE FILTER CHANGE CRITERIA
WARNING
Nuclear-Biological-Chemical (NBC) contaminated air f lters must be handled and disposed
of only by authorized and trained personnel. The unit commander or senior off cer in charge
of maintenance personnel must ensure that prescribed protective clothing (FM 3-11.4) is
used and prescribed safety measures and decontamination procedures (FM 3-11.5) are
followed. The local unit SOP is responsible for
final
disposal of contaminated air f lters.
Failure to comply may result in personnel injury or death.
NOTE
For maximum safety, it is vital the gas and particulate f lters of f lter unit M8A3 be fully
serviceable. Field maintenance is responsible for changing f lters when notif ed. Notify field
maintenance when one or more of the following conditions exist.
1. Conditions for M12A1 gas f lter replacement:
a. Physical damage or water immersion.
b. Low airf ow to masks, determined not to be caused by incorrect hose connections or low electrical power.
c. At beginning of combat conditions when use of CK (cyanogen chloride) or AC (hydrogen cyanide) is
expected.
d. As soon as possible after each AC or CK attack.
e. 5,000-mile vehicle overhaul (peacetime).
f. 1,500 hours of vehicle operation (approximately 5 months, wartime).
2. Conditions for M13 particulate f lter replacement:
a. Physical damage occurs.
b. M12A1 gas f lter is changed.
c. Particulate f lter becomes clogged, resulting in insuff cient airf ow.
END OF TASK
END OF WORK PACKAGE
0037-2