Figure 64.
Gas Particulate Filter Unit Spring
Clip.
b. Pull and lift spring clip from air intake
openings on f lter unit.
c. Set MASTER BATTERY switch and GAS
PARTICULATE switch to ON.
d. Pull hose outlet from clip at both crew
member stations.
e. Check for steady f ow of air at hose outlet
at both crew member stations.
f. Push hose outlet into clip at both crew
member stations.
g. Set GAS PARTICULATE switch to OFF.
h. Press spring clip down on f lter unit to cover
air intake opening.
i. Set MASTER BATTERY switch to OFF.