AIR CLEANER FILTER ELEMENT CLEANING OR REPLACEMENT (Sheet 4 of 5)
3.
Soak filter element in cleaning solution for 15 to 20 minutes, then gently shake it back
and forth for 2 to 3 minutes to free dirt deposits.
4.
Rinse filter element with cool water (35°F to 80°F) (2°C to 27°C) until all traces of dirt
and detergent are removed.
5.
If hose is used to rinse filter element, maximum line pressure of 40 psi should be used.
Make sure filter element is completely dry before using.
Inspect filter element after drying to be sure dust is not
caked inside element.
6.
Air dry at normal room temperature until filter element is completely dry. If circulating
air is used, temperature must not exceed 180°F (82°C).
7.
After cleaning, inspect filter element for damage to seal or ruptured filter material,
place light inside filter element, and inspect from outside. If ruptured, replace with new
filter element.
8.
Use a clean, damp rag and wipe out filter compartment.
INSTALLATION:
1.
2.
3.
filter seal.
Open door (A).
Be careful when installing filter element not to damage
Install filter element (B) by lowering it to
bottom of filter compartment (C).
Slide filter element (B) rearward to seal
element in position.
Go on to Sheet 5
Change 1
7-99