TM 5-5420-202-20-2
AIR CLEANER (ALUMINUM) CENTRIFUGAL FAN COVER AND GASKET REPLACEMENT (Sheet 3 of 3)
INSTALLATION:
1.
2.
3.
4.
5.
6.
7.
8.
9.
Position two circuit breakers (A) onto cover (B).
Install washers (C) and screws (D) to secure
circuit breakers (A) to cover (B). Using
screwdriver, tighten screws (D).
Position new gasket (E) on housing with
sealing compound.
Position cover (B) in front of housing.
Connect lead with jumpers (F) from centrifugal
fan to each circuit breaker (A).
Connect one connector from power lead
to each circuit breaker (A). (Power lead
is the one coming from side of housing.)
Check operation of air cleaner blower fan
(TM 5-5420-202-10).
Position cover (B) to housing and install
16 screws (G) lockwashers (H), and flat
washers (J) to secure cover.
Using socket and wrench, tighten screws (G).
End of Task
7-108