TM 5-5420-202-20-2
AIR CLEANER (ALUMINUM) CENTRIFUGAL FAN HOSE REPLACEMENT (Sheet 1 of 1)
TOOLS: Flat-tip screwdriver
SUPPLIES:
Silicone compound
PRELIMINARY PROCEDURES:
REMOVAL:
(Item 32, Appendix D
Remove air cleaner cover and gasket (page 7-106)
Remove air cleaner centrifugal fan (page 7-118)
1.
2.
3.
4.
Using screwdriver, loosen two clamps (A).
Slide clamps (A) onto hose (B).
Remove hose (B) from centrifugal fan (C)
and housing (D).
Inspect hose (B) and clamps (A). Replace as
necessary.
INSTALLATION:
1.
Position clamps (A) onto hose (B).
2.
Coat inside diameter of hose ends with silicone
compound and install hose (B) to centrifugal fan
(C) and housing (D).
3.
Slide clamps (A) to ends of hose. Using screwdriver, tighten clamps (A).
4.
Install air cleaner centrifugal fan (page 7-122).
5.
Install air cleaner cover and gasket (page 7-108).
End of Task