TM 5-5420-202-20-2
AIR CLEANER (ARMORED) CENTRIFUGAL FAN REPLACEMENT (Sheet 2 of 7)
REMOVAL
1.
Using socket, remove 10 screws and
lockwashers, (A) securing cover (B).
2.
Place cover (B) on housing (C).
3.
NOTE
Disconnect and tag four electrical leads
from two circuit breakers (D) mounted to
underside of cover (B).
4.
Remove cover (B).
There are two centrifugal fans in each air cleaner. Each centrifugal fan is
removed in the same way.
5.
Using screwdriver, loosen clamp (E) securing hose (F) to inlet of centrifugal fan (G).
Slide clamp onto hose.
6.
Remove hose (F) from inlet of centrifugal fan (G).
Go on to Sheet 3