TM 5-5420-202-20-2
AIR CLEANER (ALUMINUM) CENTRIFUGAL FAN REPLACEMENT (Sheet 3 of 6)
5.
Using screwdriver, loosen hose clamp (F)
securing hose (G) to centrifugal fan inlet.
6.
Slide clamp (F) away from centrifugal fan (H).
7.
Disconnect
8.
Disconnect
hose (G) from centrifugal fan (H).
electrical lead (J) from ground lead.
9.
Using 1/2 inch socket and extension, remove two screws (K), lockwashers (L), and washers (M).
10.
Carefully remove centrifugal fan (H).
11.
Disconnect jumper lead (N) from centrifugal fan lead.
Go on to Sheet 4