TM-5-5420-202-20-2

M60A1 CHASSIS, TRANSPORTING; FOR BRIDGE, ARMORED-VEHICLE-LAUNCHED; SCISSORING TYPE, CLASS 60

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE MANUAL; VOLUME 2 OF 4

OCTOBER 1985

  TM-5-5420-202-20-2 - Page 343 of 734

TM 5-5420-202-20-2
AIR CLEANER CENTRIFUGAL FAN GROUND LEAD REPLACEMENT (Sheet 1 of 2)
TOOLS: 7/16 in. combination box and open end wrench
SUPPLIES:
Lockwasher (2 required)
REFERENCE:
TM 5-5420-202-10
PRELIMINARY PROCEDURES:
Remove air cleaner centrifugal fan cover (armored,
page 7-103, aluminum, page-7-106)
Make sure MASTER BATTERY switch is OFF
(TM 5-5420-202-10)
NOTE
Remove of left or right
centrifugal fan ground lead is
the same. Left side shown.
REMOVAL:
1.
2.
3.
Disconnect two connectors (A)
from centrifugal fan leads (B).
Using wrench, remove screw (C) and
Iockwashers (D) securing ground lead (E) to
terminal boss (F).
Remove ground lead (E).
Go on to Sheet 2
7-126