TM 5-5420-202-20-2
AIR CLEANER (ALUMINUM) CIRCUIT BREAKER REPLACEMENT (Sheet 1 of 1)
TOOLS: Flat-tip screwdriver
REFERENCE:
TM 5-5420-202-10
PRELIMINARY PROCEDURE: Remove air cleaner cover (page 7-106)
REMOVAL:
1.
Using screwdriver, remove four screws (A) and lockwashers (B) securing two circuit breakers (C)
to cover (D).
2.
Remove two circuit breakers (C).
INSTALLATION:
1.
Position two circuit breakers (C) onto cover (D)
2.
Install lockwashers (B) and screws (A) to
secure circuit breakers (C) to cover (D).
Using screwdriver, tighten screws (A).
3.
Install air cleaner cover (page 7-108).
4.
Check operation of centrifugal fans
(TM 5-5420-202-10).
End of Task
7-125