TM-5-5420-202-20-2

M60A1 CHASSIS, TRANSPORTING; FOR BRIDGE, ARMORED-VEHICLE-LAUNCHED; SCISSORING TYPE, CLASS 60

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE MANUAL; VOLUME 2 OF 4

OCTOBER 1985

  TM-5-5420-202-20-2 - Page 341 of 734

TM 5-5420-202-20-2
AIR CLEANER (ARMORED) CIRCUIT BREAKER REPLACEMENT (Sheet 1 of 1)
TOOLS: 1/2 in. socket with 1/2 in. drive
Cross-tip screwdriver
Ratchet with 1/2 in. drive
REFERENCE:
TM 5-5420-202-10
NOTE
All air cleaner circuit breakers are
removed and installed the same way.
REMOVAL:
1.
Using socket, remove 10 screws (A) and Iockwashers (B) securing cover (C) to air cleaner.
2.
Using screwdriver, remove
screws
(D) and lockwashers (E) securing circuit breaker (F)
to cover (C).
3.
Remove circuit breaker (F).
4.
Disconnect two electrical leads (G).
INSTALLATION:
1.
Position circuit breaker (F) onto
cover (C).
2.
3.
4.
5.
6.
Install washers (E) and screws (D) to secure
circuit breaker (F) to cover (C). Use cross-
tip screwdriver and tighten screws (D).
Connect two electrical leads (G).
Install cover (C) and secure with 10 screws (A)
and lockwashers (B).
Using socket, tighten screws (A).
Check operation of centrifugal fans
(TM 5-5420-202-10).
End of Task
7-124


Back to Top