TM 5-5420-202-20-3
BATTERY TESTING (Sheet 3 of 5)
Testing Using Hydrometer (Sheet 2 of 2)
8.
Using correction chart (G), correct
readings recorded in step 6 to 80°F.
Example: Hydrometer shows 1.280
specific gravity.
Electrolyte temperature
is 0°F. Using correction chart (G),
note that for electrolyte temperature
of 0°F, 0.032 is to be subtracted from
hydrometer reading.
Therefore, corrected
reading is:
1.280-0.032 = 1.248.
9.
Using pencil and paper, add all six corrected
readings together and divide by 6 to
find the average reading for the battery.
10.
If average reading for battery is below
1.225, charge battery (TM 5-5420-202-10).
11.
If any two of six readings for battery are not
within 0.025 of each other, replace battery
(page 10-253).
12.
Replace rubber battery cover (page 10-256).
13.
Turn MASTER BATTERY switch to ON (TM
5-5420-202-10).
End of Task
TA249201
10-260