TM-5-5420-202-20-4

M60A1 CHASSIS, TRANSPORTING; FOR BRIDGE, ARMORED-VEHICLE-LAUNCHED; SCISSORING TYPE, CLASS 60

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE MANUAL; VOLUME 4 OF 4

OCTOBER 1985

  TM-5-5420-202-20-4 - Page 245 of 534

TM 5-5420-202-20-4
SMOKE GENERATOR SWITCH OR GUARD REPLACEMENT (Sheet 2 of 2)
INSTALLATION:
1.
Be sure ON position is up and position switch (A) to backside of mounting bracket (B).
2.
Position guard (C) over switch (A). Be sure toggle lever on switch is down.
3.
Using screwdriver, install two screws and lockwashers (D) to secure guard (C) and switch
(A) to bracket (B).
4.
Connect switch-to-light indicator lead (E) to light indicator connector (F).
End of Task
5.
Connect switch connector (G) to harness
connector.
6.
Start engine (TM 5-5420-202-10) and
run until normal operating temperatures
are attained.
Run engine at 1600 rpm.
7.
Place SMOKE GENERATOR switch
(A) to ON.
8.
Observe operation of smoke generator.
9.
Place SMOKE GENERATOR switch
(A) to OFF.
10.
Shut down engine (TM 5-5420-202-10).
TA248744
21-3