TM 5-5420-202-20-4
SMOKE GENERATOR WIRING HARNESS TO BULKHEAD LEAD REPLACEMENT (Sheet 1 of 1)
TOOLS:
Electrical connector repair tool kit
Long nosed pliers (needle nose)
Slip joint pliers
REFERENCE:
TM 5-5420-202-10
PRELIMINARY PROCEDURES:
Remove ground terminals from batteries (page 10-268)
Remove starter harness bulkhead cable disconnect
(page 10-269).
REMOVAL:
1.
2.
3.
4.
Manually pull apart connectors (A and
B).
Using slip joint pliers, unscrew nut (C)
from plug assembly (D).
Using remover, push out pin from position
“A” in plug assembly (D).
Remove lead (E) from nut (C). Throw
lead (E) away.
INSTALLATION:
1.
Thread new lead (E) through nut (C).
2.
Using needle nose pliers, insert lead (E)
pin into position “A” in plug assembly (D).
3.
Using slip joint pliers, tighten nut (C)
onto plug assembly (D).
4.
Install starter harness bulkhead cable disconnect (page 10-270).
5.
Connect ground terminals to batteries (page 10-268).
End of Task