TM 5-5420-202-20-4
SMOKE GENERATOR HULL WIRING HARNESS REPLACEMENT (Sheet 5 of 5)
11.
Position wiring harness (A) under five straps (P).
12.
Using socket, install and tighten five screws (Q), washers (R), and lockwashers (S) to secure
ends of straps (P).
13.
Start engine (TM 5-5420-202-10) and run until normal operating temperatures are attained.
Run engine at 1600 rpm and activate smoke generator. Observe operation. Shut off
smoke generator. Shut down engine.
14. Install hull interior floor plate. (TM 5-5420-228-24).
End of Task
TA248756
21-15