TM-5-5420-202-20-4

M60A1 CHASSIS, TRANSPORTING; FOR BRIDGE, ARMORED-VEHICLE-LAUNCHED; SCISSORING TYPE, CLASS 60

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE MANUAL; VOLUME 4 OF 4

OCTOBER 1985

  TM-5-5420-202-20-4 - Page 256 of 534

TM 5-5420-202-20-4
SMOKE GENERATOR HULL WIRING HARNESS REPLACEMENT (Sheet 4 of 5)
INSTALLATION:
2.
3.
4.
5.
6.
7.
8.
9.
10.
Go on to Sheet 5
Connect smoke generator switch con-
nector (B) to wiring harness connector
(C).
Place clamp (D) on wiring harness (A).
Manually install screw (E) through clamp
(D) and support (F).
Install lockwasher and nut (G) on screw
(E).
Using socket and 7/16 inch wrench,
tighten screw (E).
Connect wiring harness connector (H)
to lead connector (J).
Manually connect connector (K) to air
cleaner blower motor relay (L).
Use spanner wrench to tighten connector
(K).
Connect connector (M) to wiring harness
connector (N).
TA248755
21-14