Second Technician (Operator's Station)
•
Move ball valve to “TRAVEL” position.
•
Shut engine off.
•
Cycle bridge launching control levers.
First Technician (Overhead Cylinder)
•
Remove pressure gage or STE/ICE from
counterbalance valve T2 and install gage plug.
Second Technician (Operator's Station)
•
Start engine.
•
Move ball valve to “LAUNCH” position.
•
Set engine speed at 1800 rpm.
•
Raise overhead cylinder control lever
momentarily.
First Technician (Top Deck)
•
Visually check that holddown cylinder does
release.
Check that hold down cylinder does release.
10
FROM STEP 6
•
System is operational.
•
Install overhead cylinder armor
(page 3-224).
•
Perform launch and retrieve
procedures (TM-10).
YES
NO
Change 3
2-68.5
11
TM 5-5420-228-24
DETAILED TROUBLESHOOTING PROCEDURE
LAUNCHER OPERATION – HYDRAULICS
(Continued)
Symptom-1.1
Does holddown cylinder release?