Change 3
2-90.3/(2-90.4 blank)
TM 5-5420-228-24
Symptom-5.1
First Technician (Operator's Station)
•
Shut engine OFF.
•
Move ball valve to “TRAVEL” position.
•
Cycle bridge launching control levers.
Second Technician (Launcher Tongue)
•
If STE/ICE is available, proceed to test No. 51
(page 2-58.1) to test tongue dual
counterbalance valve T2 quick disconnect
fitting.
•
If STE/ICE is not available, connect adapter
hose to gage and adapter to tongue dual
counterbalance valve T2 quick disconnect
fitting.
First Technician (Operator's Station)
•
Start engine.
•
Move ball valve to “LAUNCH” position.
•
Set engine speed at 1800 rpm.
•
Raise tongue cylinder control lever.
Second Technician ((Launcher Tongue)
•
Check if pressure gage or STE/ICE is between
3550 to 3650 psi.
Check tongue dual counterbalance valve for
pressure setting of between 3550 to 3650 psi.
Is pressure between 3550 to 3650 psi?
5
•
Replace cartridge (C2) in
tongue dual counterbalance
valve (page 3-204.64).
•
If still cannot be brought
within tolerance, notify
support maintenance of
defective valve bank.
•
Remove pressure gage
assembly from T2.
•
Replace tongue cylinder.
6
7
NO
YES
DETAILED TROUBLESHOOTING PROCEDURE
LAUNCHER OPERATION – HYDRAULICS
(Continued)