C
. Electrical Receptacle Connector - Maintenance Instructions.
REMOVAL
CAUTION
To avoid damage to discharger, do not put strain on wires.
Make sure electrical receptacle connector key location is marked on cover plate so it can be
installed in the same place. If not done, wires can be damaged.
1 Discharger Base
a. Cover plate (1)
Mark electrical receptacle connector (2) key
location.
b. Screws (3)
Remove eight screws.
c. Cover plate (1) and
Remove from discharger base (5).
gasket (4)