lNSTALLATION
Do not break strands
Ground wire (1)
CAUTION
on wire when stripping insulation.
a. Cut new wire about 8 inches long.
b.
c.
d.
e.
f.
g.
h.
Strip insulation to length of terminal sleeve. in-
sert wire into terminal. Crimp terminal and sol-
der (item 9, app D). See TB SIG 222.
Cut two pieces of insulation sleeving 3/4 inches
long and slide to center of wire.
Slide one insulation sleeving over terminal
sleeve and heatshrink.
Strip insulation to depth of solder well of pin C.
Insert ground wire into solder well and solder
(item 9, app D) to pin C. See TB SIG 222.
Slide insulation sleeving over soldered connec-
tion and heatshrink.
Insert pin C into electrical receptacle connector (2)
Use screw (3) and lock washer (4) to connect
terminal (5) to discharger base (6) and tighten.
2-45
TM 9-1040-267-20&P