TM 9-1240-401-34&P
5-8 DIRECT SUPPORT SYMPTOM INDEX
Troubleshooting
Procedure
(Page)
LAMP ASSEMBLY
Reticle is not illuminated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.
. . . .
5-7
AZIMUTH KNOB
Azimuth knob does not function correctly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.. 5-7
ELBOW ASSEMBLY
Lens is fogged or condensation is present . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. 5-8
5-9. DIRECT SUPPORT TROUBLESHOOTING
MALFUNCTION
TEST OR INSPECTION
LOCATION
CORRECTIVE ACTION
1.
2.
LAMP ASSEMBLY
RETICLE IS NOT ILLUMINATED.
Observe visually.
a.
b.
c.
Replace LED (1) (ref. para 5-14
or 5-15).
Replace lamp assembly (2) (ref. para
5-14 or 5-15).
Replace variable resistor (ref. para
5-14 or 5-15).
AZIMUTH KNOB
AZIMUTH KNOB (4) DOES NOT FUNCTION
CORRECTLY.
Rotate azimuth knob.
Replace
5-13).
azimuth knob (4) (ref. para
5-7