11
12
13
14
15
16
17
18
19
Install electrical lead (15) with wire and lug terminal
(16) attached.
Using 11/1 6 and 45/64 inch tubular spanner
wrench, install threaded ring (14).
Install housing (13) on M117 panoramic telescope
and secure with machine screw (12).
Solder three lug terminals (10) on wires (11) using
solder and flux.
Install three lug terminals (10) with wires (11) at-
tached on housing (13) and secure with machine
screw (9), new Iockwasher (8) and machine screw
(7).
Install access cover (6) and secure with four ma-
chine screws (5).
Install LED (4).
Install electrical connector cover (3) and secure
chain with new Iockwasher (2) and machine screw
(1).
NOTE
Repeat steps 8 through 12, then 17 and 18 for
second lamp assembly.
Purge and charge optics (ref. TM 750-116).
5-19