ARMY TM 9-1290-365-24&P
D.7.12.6 FUNCTIONAL TEST. Refer to para. D.7.13.4 for troubleshooting procedures.
a. Turn on PC.
b. Load software SPC1553.EXE.
c. Set ACCL switch to OFF
d. Set switch S6 to position MVP-II.
e. Set switch S4 to position DOPP.
NOTE
During the test, the message “AAAA Stay Alive” may appear several times. (AAAA is a
sequence no.) This is normal operation.
f.
Turn on the 1553 simulator.
g. Using the mouse or keyboard on the PC choose “Start” from the EVENT menu. Verify the following
message on screen:
“AAAA BIT FAILURE FALSE YYY.Y Ver X.X”
“AAAA Stay alive”
where:
AAAA = message sequence no.
YYY.Y = 395±5m/sec.
X.X = last version no.
h. Choose “BIT Status” from the EVENT menu. Verify the following message on screen:
“AAAA BIT FAILURE FALSE YYY.Y Ver X.X”
where
AAAA = message sequence no.
YYY.Y = 395 ± 5m/sec.
X.X = last version no.
i.
Set velocity range from the EVENT menu to 100m/sec minimum,1000m/sec maximum.
j.
Set the function generator to 14KHz ±1Hz and amplitude 400 ±l0mVp-p.
k. Choose “SHELL” option from the EVENT menu. Turn ACCL switch to ON and then to OFF. Verify
ANT. PWR led is on for approximately 3 seconds. Verify the following message on screen:
“AAAA Velocity YYY.Y TRUE”.
where:
AAAA = message sequence no.
YYY.Y = 199.10 ±0.5m/sec.
I.
Set function generator to 50KHz ±1Hz.
m. Choose “SHELL” option from the EVENT menu. Turn ACCL switch to ON and then to OFF. Verify
ANT PWR led is on for approximately 3 seconds. Verify the following message on screen:
“AAAA VELOCITY YYY.Y TRUE”
where:
AAAA = message sequence no.
YYY.Y = 710.9 ±0.6m/sec
n. Choose “SHELL” option from the EVENT menu. Lightly tap with a finger on the MVP CCA, near
the acceleration switch housing, to activate the switch. Verify ANT PWR led is on for
approximately 3 seconds. Verify the following message on screen:
“AAAA VELOCITY YYY.Y TRUE”
where:
AAAA = message sequence no.
YYY.Y = 710.9 ±0.6m/sec
o. Choose “SHUTDOWN” option from the EVENT menu, verify the following message on screen:
“SHUTDOWN COMPLETE”.
p. For versions AY6707288-4 and AY67010314, turn off power switch on tester wait about 5 seconds
and turn on the power switch.
Change 1
D-95