TM-9-2320-209-10-1

2 1/2-TON, 6X6, M44A1 AND M44A2 SERIES TRUCKS (MULTIFUEL)

TECHNICAL MANUAL; OPERATION, INSTALLATION AND REFERENCE DATA; OPERATOR LEVEL

SEPTEMBER 1980

  TM-9-2320-209-10-1 - Page 445 of 549

TM
9-2320-209-10-1
e.
Operating the Fuel Burning Power Plant Heater.
FRAME 1
NOTE
The fuel burning power plant heater is designed to keep the
engine compartment warm when vehicle is not in use. This
heater should not be used while operating the vehicle.
1.
Make sure heater coolant outlet shutoff cock (1) is fully open (turn left).
2.
Make sure heater coolant inlet shutoff cock (2) is fully open (turn left).
GO TO FRAME 2
4-391


Back to Top