TM-9-2320-209-20-2-1

2½-TON, 6X6, M44A1 AND M44A2 SERIES TRUCKS (MULTIFUEL)

TECHNICAL MANUAL; TROUBLESHOOTING; ORGANIZATIONAL LEVEL; VOLUME 2 OF 3; PART 1 OF 2

MAY 1981

  TM-9-2320-209-20-2-1 - Page 251 of 645

TM 9-2320-209-20-2-1
From step 11
Check for +24 volts DC (from batteries)
through magnetic starter relay
SOLDIER B:
SOLDIER A:
SOLDIER B:
Set multimeter to
measure +24 volts
DC. Refer to
test equipment
procedures index
Put multimeter - lead
on a good ground
Put multimeter + lead
on lead 6 terminaI of
magnetic starter relay
Step on starter button
Read multimeter.
Multimeter should
measure +24 volts DC
Does multimeter measure +24 volts DC?
MAGNETIC
Replace lead 6
Set ACCESSORY switch to OFF
Replace lead 6. Tell direct
support maintenance
Figure 25-1 (Sheet 8 of 25)
25-9


Back to Top