GO
‘
●
Check lead 214 starter terminal for
+24 volts
D C
SOLDIER B:
●
Put multimeter - lead
on a good ground
●
Put multimeter + lead
on lead 214 terminal
of starter
SOLDIER A:
●
Step on starter button
SOLDIER B:
●
Read multimeter.
Multimeter should
measure +24 volts DC
Does multimeter measure +24 volts DC?
TM 9-2320-209-20-2-1
MAGNETIC
●
Replace lead 214
●
Set ACCESSORY switch to OFF
●
Replace lead 214. Tell
direct support maintenance
●
Replace starter
●
Set ACCESSORY switch to OFF
●
Replace starter. Refer to Vol 3,
chapter 7, para 7-10 or 7-11
Figure 25-1 (Sheet 10 of 25)
TA 114218
25-11