TM 9-2320-209-20-2-1
Symptom
EMPERATURE GAGE DOES NOT WORK. ALL OTHER
I
When measuring voltage +24 volts
means a range of +23 to +26 volts DC
Park truck
I
Refer to TM 9-2320-209-10 I
7’
Check for +24 volts from temperature
gage to sending unit
Set ACCESSORY switch to OFF
Take off lead 33 contact from
temperature sending unit
Set ACCESSORY switch to ON
I
Set multimeter to measure +24 volts
DC. Refer to test equipment
procedures index
Put multimeter
- lead on a good
ground
Put multimeter + lead on lead
33 contact
Read multimeter. Multimeter
should read +24 volts DC
Does mu Itimeter measure
less than +24 volts DC?
m
TEMP
SEND
.
TA 114444
25-237
Figure 25-29 (Sheet 1 of 6)


Back to Top