TIVI 9-2320-209-20-2-1
GO
(
4
●
Replace temperature gage
●
Set ACCESSORY switch to OFF
●
Put lead 33 contact back on
temperature sending unit
●
Replace temperature gage.
Refer to Vo13, chapter7,
para 7-13
L
1
1-
●
Check for VOI tage to temperature gage
●
●
●
●
Set ACCESSORY switch to OFF
Take off instrument cluster from
instrument panel. Refer to Vol
3, chapter 7, para 7-12
Put iumper wire from instrument
cluster to a good ground
Take off lead 33 from temperature
gage
●
●
●
●
●
Set ACCESSORY switch to ON
Check that multimeter is
stil I in
+24 volts DC position
Place multimeter
- lead on a good
ground
Place multimeter + lead on lead 33
contact
Read mu I timeter.
Mu Itimeter
shou Id measure +24 vo I ts DC
Does mu I timeter measure +24 volts DC’?
INSTRUMENT
\
\
CLUSTER
\
JUMPER WIRE
u
“URE
GO
25-238
.4445
Figure
25-29 (Sheet 2 of 6)