TM-9-2320-209-20-3-1

2½-TON, 6X6, M44A1 AND M44A2 SERIES TRUCKS (MULTIFUEL)

TECHNICAL MANUAL; TROUBLESHOOTING; ORGANIZATIONAL LEVEL; VOLUME 3 OF 3; PART 1 OF 4

MAY 1981

  TM-9-2320-209-20-3-1 - Page 166 of 830

TM 9-2320-209-20-3-1
b.
Removal.
WARNING
Do not permit smoking, sparks or open
flame within 50 feet of work area. Fuel
could explode, causing injury to person–
nel and damage to equipment.
1.
Put container under nut ( 1).
2.
Working under truck using 9/16-inch wrench, hold nut ( 1). Using 7/16-inch
combination box and open end box wrench, unscrew and take off tube nut (2) .
Let fuel drain into container.
GO TO FRAME 2
TA 08554 6
4-78