TM-9-2320-209-20-3-1

2½-TON, 6X6, M44A1 AND M44A2 SERIES TRUCKS (MULTIFUEL)

TECHNICAL MANUAL; TROUBLESHOOTING; ORGANIZATIONAL LEVEL; VOLUME 3 OF 3; PART 1 OF 4

MAY 1981

  TM-9-2320-209-20-3-1 - Page 199 of 830

TM 9-2320-209-20-3-1
c.
Replacement.
WARNING
Dry cleaning solvent is flammable. Do not
use near an open flame. Keep a fire ex-
tinguisher nearby when solvent is used.
Use only in well-ventilated places. Failure
to do this may result in injury to personnel
and damage to equipment.
NOTE
Clean all fuel line fittings with solvent. Be-
fore putting fittings together, put a thin
coat of sealer compound on threads of
fittings.
1.
Screw two elbow fittings ( 1 and 2) into fuel inlet solenoid valve (3) and hand
tighten.
2.
Using 7/16-inch open end wrench, tighten elbow fittings ( 1 and 2) in fuel inlet
solenoid valve. Position each elbow fitting as noted.
3.
Screw one elbow fitting (4) into the hole on the side shown of fuel return
solenoid valve (5) and hand tighten.
4.
Using 7/16-inch open end wrench, tighten elbow fitting (4) in fuel return
solenoid valve ( 5).
Position elbow fitting as noted.
GO TO FRAME 2
TA 08756 6
4-111


Back to Top