TM 9-2320-209-20-3-1
Section IX. CHASSIS HARNESS
7-59.
GENERATOR-TO-REGULATOR HARNESS REMOVAL, REPAIR, AND REPLACE-
MENT (TRUCKS WITH ENGINES LDS 427-2, LD 465-1, AND LDT 465-IC).
TOOLS:
Spanner wrench
Soldering iron
SUPPLIES:
Sandpaper or crocus cloth
Electric insulating tape, MIL-T-50886
PERSONNEL: One
EQUIPMENT CONDITION:
Truck parked, engine off, handbrake set.
a.
Preliminary Procedure. Disconnect battery ground cable. Refer to para 7-58.
b.
Removal.
FRAME 1
NOTE
Note the way generator-to-regulator harness is routed
so that it can be put back the same way.
1. Using spanner wrench, unscrew and take off generator–to–regulator harness
connector (1) from regulator (2).
2.
Using spanner wrench,
unscrew and take off generator–to–regulator harness
connector (3) from generator (4).
3. Take out generator-to-regulator harness (5).
END OF TASK
7-227