TM 9-2320-209-34-2-1
(2) Cleaning, inspection, and repair.
FRAME 1
1.
2.
4.
WARNING
Dry cleaning solvent is flammable. Do not use near an
open flame. Keep a fire extinguisher nearby when sol-
vent is used. Use only in well-ventilated places.
Failure to do this may result in injury to personnel and
damage to equipment.
Clean compensator body (1) and cage cover (2) with dry cleaning solvent.
Check that all finished surfaces on compensator body (1) and cage cover (2)
have no scratches. If finished surfaces are scratched, rub out any scratches
with honing stone. If scratches will not rub out easily, get a new compensator
body (1) and cage cover ( 2).
NOTE
Do not take out tube fitting (3) or pipe plug (4).
Check that tube fitting (3) and pipe plug (4) are not damaged. If air tube
fitting or pipe plug is damaged, get a new compensator body (1) and cage
cover (2).
GO TO FRAME 2