TM-9-2320-209-34-2-2

2½-TON, 6X6, M44A1 AND M44A2 SERIES TRUCKS (MULTIFUEL)

TECHNICAL MANUAL; MAINTENANCE; DIRECT SUPPORT AND GENERAL SUPPORT LEVEL; VOLUME 2 OF 2; PART 2 OF 3

MAY 1981

  TM-9-2320-209-34-2-2 - Page 392 of 899

TM 9-2320-209-34-2-2
17-33. WATER DISCHARGE PIPE REPAIR (TRUCKS M50A2 AND M50A3).
TOOLS:
No special tools required
SUPPLIES:
Solvent, dry cleaning, type II (SD-2), Fed. Spec P-D-680
PERSONNEL: One
EQUIPMENT CONDITION:
Truck parked, engine off, handbrake set.
Preliminary Procedure. Remove discharge pipe. Refer to
TM 9-2320-209-20.
b. Cleaning, Inspection, and Repair.
WARNING
Dry cleaning solvent is flammable. Do not use near
an open flame. Keep a fire extinguisher nearby when
solvent is used. Use only in well-ventilated places.
Failure to do this may result in injury to personnel
and damage to equipment.
1.
Clean discharge pipe (1) with dry cleaning solvent.
2.
Check that discharge pipe (1) has no cracks or holes.
3.
If discharge pipe (1) is damaged, throw it away and get new one.
NOTE
Follow-on Maintenance Action Required:
Replace discharge pipe. Refer to TM 9-2320-209-20.
END OF TASK
17-375


Back to Top