TM-9-2320-272-23-1

TRUCK, 5-TON, 6X6, M939, M939A1, AND M939A2 SERIES TRUCKS (DIESEL)

TECHNICAL MANUAL; FIELD MAINTENANCE MANUAL; VOLUME 1 OF 5

SEPTEMBER 2012

  TM-9-2320-272-23-1 - Page 1254 of 1313

FIELD MAINTENANCE
CONTROL PANEL LIGHTS WORK, SYSTEM FAILS TO INFLATE OR DEFLATE
INITIAL SETUP:
Tools and Special Tools
Tool Kit, General Mechanic's: Automotive
(Volume 5, WP
0826, Table 1, Item 56)
Goggles, Industrial
(Volume 5, WP
0826, Table 1, Item 20)
Multimeter
(Volume 5, WP
0826, Table 1, Item 34)
Soap Solution
Test Set, Electronic Systems
(Volume 5, WP
0826, Table 1, Item 51)
Personnel Required
(2)
References
Point to Point Schematics
References (cont.)
WP
0128
Volume 2, WP
0322
Volume 2, WP
0324
Volume 5, WP
0805
Volume 5, WP
0810
Equipment Condition
Vehicle parked and engine shut down.
(TM
9-2320-272-10)
TROUBLESHOOTING PROCEDURE
CONTROL PANEL LIGHTS WORK, SYSTEM FAILS TO INFLATE OR DEFLATE
NOTE
Conduct these malfunction tests if control panel lights work, but the system fails to inflate or
deflate. This procedure will check for a problem with air lines between pneumatic controller
and wet tank. It will also check for a faulty air supply from the vehicle air compressor, CTIS
wiring harness, pneumatic controller, electrical lead at wet tank pressure switch, and pressure
switch.
TM 9-2320-272-23-1
0149
0149-1


Back to Top