ENGINE CRANKS BUT WILL NOT START IN COLD WEATHER (FUEL SYSTEM OPERATING PROPERLY) -
Continued
c.
Connect red lead to circuit 570 terminal on fuel pressure switch.
d.
Connect black lead to good ground.
e.
Multimeter will display volts DC.
f.
Crank engine and depress ether start switch.
NOTE
If battery voltage is present, circuit 570 wire is faulty.
g.
Meter reading should be greater than 18 VDC.
CONDITION/INDICATION
DOES CIRCUIT 570 WIRE CONDUCT BATTERY VOLTAGE TO ETHER VALVE?
DECISION
YES - Go to Step (4).
NO - Repair circuit 570 wire to ether valve (Volume 3, WP
0352). Go to Step (10) to verify problem is solved.
TM 9-2320-272-23-1
0021
0021-5