LOW AIR PRESSURE WARNING BUZZER WILL NOT SHUT OFF (AIR PRESSURE GAUGES AT NORMAL
SYSTEM PRESSURE) - Continued
c.
Install wires 578 and 578A to primary low air pressure switch.
d.
Disconnect wires 57 and 578A from secondary low air pressure switch.
e.
Connect multimeter red lead to contact end of pressure switch. Refer to point to point schematics.
f.
Connect multimeter black lead to other contact end of pressure switch.
g.
Meter reading should be less than 300 ohms.
CONDITION/INDICATION
IS SECONDARY LOW AIR PRESSURE SWITCH WORKING PROPERLY?
DECISION
NO - Replace secondary low air pressure switch (Volume 2, WP
0342). Go to Step (6) to verify problem is
solved.
YES - Go to Step (3).
TM 9-2320-272-23-1
0110
0110-5