LOW AIR PRESSURE WARNING BUZZER WILL NOT SHUT OFF (AIR PRESSURE GAUGES AT NORMAL
SYSTEM PRESSURE) - Continued
STEP
4.
IS WIRE 578A IN GOOD CONDITION?
a.
Place battery switch to OFF position.
b.
Install wire 57 to secondary low air pressure switch.
T0107DAA
578
57
578A
Figure 4.
Pressure Switch Wire 578A.
TM 9-2320-272-23-1
0110
0110-8